Interface Probes - Teradyne / GenRad

 
P/N
Cart

Probe P/N 100-PRG2503L

100-PRG2503L Interface Probes by Teradyne/GenRad

Interface Probes

The following probes are used in Teradyne/GenRad's 1800 Series 7878, 8852, 8855 testers for electromechanical contact between the fixture and tester. These part numbers are QA’s recommended direct replacements.

Teradyne/GenRad Testers:
1800 Series 7878, 8852, 8855
For more 100-25 Series Probe options, Click Here


For Socket details, Click 100-SDN250R



 

100-PRG2503L Specifications

Tube Material
Letter Material Average Resistance     Current Rating1
SS @ 204°C
G Nickel silver/OD gold plated < 15 mOhms     17.3 Amps
Tip Style
Digit Material/Finish
03 Heat treated BeCu/plated gold over nickel
Spring Force
Letter Spring Force Preload @ 2/3 Stroke Material Cycle Life @ Stroke
L Low 1.3 [37] 3.5 [99] SS 1M @ .167 [4.24]
 

1Current Rating is affected by spring material and lubrication choices. Standard lubrication has a 204 ̊C maximum operating temperature limit.
Before using probes near these current limits, please refer to Current Carrying Capacity and Operating Temperature Application Notes.